When we intend to buy a generator for use, besides price, design and brand, it is just as important, when deciding whether to buy, to know whether it reaches the design capacity stated by the manufacturer.
External factors such as appearance and smooth operation can be checked by eye, but whether it reaches design capacity and carries the load per the manufacturer's specifications requires testing equipment.

Generator load bank is a measuring device that checks whether a generator reaches its design capacity and carries load as well as the manufacturer states.
There are two types of load bank:
1. Resistive load bank
2. Saltwater load bank
Each type has its own advantages, but the resistive load bank is used more often because it is easier to measure and operate. Another advantage is that a load test can run for 8–12 hours, whereas a saltwater load bank runs for a shorter time and can only be used with small generators.
As is known, load testing a generator means testing it under load, which can be a real load or a dummy load.
– With a real load to test (for example, a real electrical network that is operating normally and we connect the generator under test to that system), we simply adjust the generator voltage, P and Q to see whether the measured parameters match the advertised ones. However, this is very dangerous for the real system because the generator may fall short of requirements or fail.
– Without a real load, use a dummy load, i.e. the equipment above: the resistance can be increased gradually and evenly to monitor the generator's load performance easily and to learn values such as current, power, noise, and engine operation.
We can run this test continuously for 1 – 8 hours; the longer it runs, the better you can judge the generator's stability under load.
The following outcomes are possible during a load test:
– Underloaded generator: the generator does not deliver its design capacity
– Fully loaded generator: the generator delivers its design capacity
You can also tell whether the generator can carry load well by watching, during the test, whether the engine takes the load smoothly as the load increases. If it gives off a lot of black smoke as load rises, the engine is somewhat underpowered. If there is little smoke, the generator is good and worth buying.

Thien Quang Industrial Equipment Co., Ltd supplies high-quality generator load banks at reasonable prices, able to test large generators from 10 – 3000 kVA.
Contact us now for the best advice and service:
If you are interested in our load bank rental service, please Contact us with us for detailed advice and the most cost-effective solution – 0911888247, 0888999247
You may also be interested in
Head office: 316 Le Van Sy, Tan Son Hoa Ward, Ho Chi Minh City, Vietnam
Hotline : 0911 888 247 - 0888 999 247
Email : info@247power.vn